Digital
microhmmeter |
||||||||||||||||||||
MOM
6-200-01D |
||||||||||||||||||||
Microohmmeter digital is designed to measure low resistances in the range of 0,01 mO to 400 mOm | ||||||||||||||||||||
(contact resistance of switches, sockets, fuse blade terminals, bus connections, line connections, etc.) at the | ||||||||||||||||||||
output 6V voltage and current up to 200A, as well as for the process run these elements. | ||||||||||||||||||||
Attention! Microhmmeter can be a long time to measure the contact resistance at the output current is 200A, | ||||||||||||||||||||
which allows the oil to break or an oxide film on the contacts, you can not do microhmmeter low output current, | ||||||||||||||||||||
or even a short-term high current. | ||||||||||||||||||||
After the measurement session, all sessions can be viewed on a computer by connecting a cable USB. | ||||||||||||||||||||
The measuring rage of resistance and the desired output current is
given from the keyboard. |
||||||||||||||||||||
By electromagnetic interference (EMI) device complies with EN55022. | ||||||||||||||||||||
The device is designed to operate in a temperate climate with
temperature the external environment of |
||||||||||||||||||||
-20 to +40°C and relative humidity to 80% plus 25°C . | ||||||||||||||||||||
Excellent
features of unit:
|
||||||||||||||||||||
- continuous operation at a maximum current 200A; | ||||||||||||||||||||
- automatic switching on (off) fans; | ||||||||||||||||||||
- thermal
protection; |
||||||||||||||||||||
- highly reliable and fire safe; | ||||||||||||||||||||
- shock-rugged design that allows measurements in laboratory and on-site. | ||||||||||||||||||||
Technical specifications and features of unit: |
||||||||||||||||||||
- input voltage,V ........................................................................................................................ up 176 to 253; | ||||||||||||||||||||
- input frequency, Hz ............................................................................................................................. 40-60; | ||||||||||||||||||||
- output power
(max),
W
.......................................................................................................................
1200; |
||||||||||||||||||||
- output voltage
(max), V
............................................................................................................................
6; |
||||||||||||||||||||
- output current, A
.........................................................................................................
10, 20, 50, 100, 200; |
||||||||||||||||||||
- share factor of
the input current,%
........................................................................................................
0,95; |
||||||||||||||||||||
- relative
accuracy,%
................................................................................................................................
0,5; |
||||||||||||||||||||
- efficiency, %, no less ................................................................................................................................ 84; | ||||||||||||||||||||
- dimensions, mm ...................................................................................................................... 420х330х170; | ||||||||||||||||||||
- weight, kg, no more .................................................................................................................................. 8; | ||||||||||||||||||||
Measuring ranges (current and resistance)
|
||||||||||||||||||||
KP DELTA, 38
Tekstylna st,
Ternopil, Tel /Fax ( +38 0352) 255 852, tel ( +38 0352) 430
386 |