Digital microhmmeter

  MOM 6-200-01D

          Microohmmeter digital is designed to measure low resistances in the range of 0,01 mO to 400 mOm
(contact resistance of switches, sockets, fuse blade terminals, bus connections, line connections, etc.) at the
output 6V voltage and current up to 200A, as well as for the process run these elements.
         Attention!  Microhmmeter can be a long time to measure the contact resistance at the output current is 200A,
which allows the oil to break or an oxide film on the contacts, you can not do microhmmeter low output current,
 or even a short-term high current.
         After the measurement session, all sessions can be viewed on a computer by connecting a cable USB.
         The measuring rage of resistance and the desired output current is given from the keyboard.
         By electromagnetic interference (EMI) device complies with EN55022. 
         The device is designed to operate in a temperate climate with temperature the external environment of
        -20 to +40°C and relative humidity to 80%  plus 25°C .

  Excellent features of unit:
continuous operation at a maximum current 200A;
- automatic switching on (off) fans; 
- thermal protection;
highly reliable and fire safe;
- shock-rugged design that allows measurements  in laboratory  and on-site.

Technical specifications and  features of unit:

- input voltage,V ........................................................................................................................ up 176 to 253;
- input frequency, Hz ............................................................................................................................. 40-60;
- output power (max), W .......................................................................................................................  1200;
- output voltage (max), V ............................................................................................................................   6;
- output current, A .........................................................................................................  10, 20, 50, 100, 200;
- share factor of the input current,% ........................................................................................................ 0,95;
- relative accuracy,% ................................................................................................................................ 0,5;
- efficiency, %, no less ................................................................................................................................ 84;
- dimensions, mm ...................................................................................................................... 420х330х170;
- weight, kg, no more .................................................................................................................................. 8;
 
Measuring ranges (current and resistance)

 

Output current

(А)

Permissible 
measured 
resistance ()
The minimum resistance 
at which the reduced error is 0.5%
(μOhm)

10

0…400

750

20

0…200

375

50

0…80

150

100

0…20

80

200

0…5

40


  For further details, please call:

                  KP DELTA38 Tekstylna st, Ternopil, Ukraine, 46016

Tel /Fax ( +38 0352) 255 852, tel ( +38 0352) 430 386

              E-mail: delta@delta.ua ,  www.delta.ua , www.delta.te.ua